The Use Of Slit Lamp Biomicroscopy
Oct 27, 2017

The use of slit lamp biomicroscopy

1. angle method

It is the most commonly used method that the fracture system is observed with 45 degrees, the position of the basin and the mirror of the mirror. In front of the slanted method can observe most lesions, such as conjunctival papilla proliferation, conjunctival follicle, trachoma, corneal foreign body, corneal scar nebula, the anterior lens capsule pigment and lens opacity etc.. This method is mainly to check the color and shape of the eye changes, to determine the lesions.

2 reflective method

When the slit lamp shines into the eye and meets the smooth interface of the front and back of the cornea, the phenomenon of reflection will occur. At this point, if the mirror is rotated and the reflected light enters the microscope, a bright light will be seen at a glance when viewed with a microscope. Before and after the moving mirror can see the reflection of the surface of the fine change. If the angle between the slit lamp and the microscope is rotated to change the position of the irradiation, without moving the microscope, the reflected light can also be achieved. This method can be used to examine corneal edema, small corneal bubbles, corneal epithelial exfoliation, corneal ulcer healing scar, anterior capsule wrinkles, posterior capsule reflection or color reflection. http://www.mocular.net

3 after irradiation

The basic method with slanted focusing method. But at this point the observer does not look at the clear lighted area of the state, but turns his gaze to the other side of the field of vision. For example: slit from the right side of light microscope, focusing on cornea, slit beam through the cornea to the iris, forming a fuzzy split spot; the line of sight to the spot in front of the iris cornea part of observation, can be seen in the light on the background of corneal lesions. When the corneal neovascularization or other opaque objects for the organization, will appear opaque points or lines in bright background. This method is suitable for inspection of KPS, deep corneal foreign body, deep corneal vascular, corneal vascular gate etc..

4. diaphragm adjustment method

By adjusting the slit rotating handle, direction of rotation to the left or right, can make a straight crack by rotation to the horizontal position, when using horizontal fracture for optical section, the slit lamp of the pot in the middle, the angle between the arm and the slit lamp microscope... When the aperture is large, the slit image with different length can be obtained, and the long slit image is generally used for the eye sweeping and ocular diseases. It is possible to shorten the length of slit image so as to reduce the glare. With the mirror or touch the mirror or the rear glass body fundus examination, slit like length shall be shortened properly. Blue filters are usually used for fluorescence observation, and green filters are used to observe blood vessels.